5514 County Road J
Woodruff, WI 54568
Borgen Well & Pump (715) 555-0137
borgenwell.example
Pump Installation Report and Water Test
Customer: Raymond and Margaret Ostrander
Well location: 8815 Skein Lake Road, Minocqua (pump house, 20 feet north of the cabin)
Date of work: July 21, 2020
Reason for the call: No water. The old pump, set in 1994, had failed.
The well
Type Drilled, 6-inch steel casing
Total depth 96 feet
Water standing at 31 feet below the top of the casing
Well cap New vermin-proof cap fitted
What we installed
Pump Submersible, 1/2 horsepower, 10 gallons a minute, 230 volt
Pump set at 82 feet
Drop pipe and wire 82 feet of 1-inch poly pipe; new 12-gauge pump cable
Pressure tank 32 gallons, in the pump house
Pressure switch On at 40 pounds, off at 60
Tank pre-charge 38 pounds
Electrical Breaker 14 in the cabin panel, two-pole, 20 amp, marked WELL
Yield after one hour of pumping 9 gallons a minute, water clear
Water test, sample drawn at the kitchen tap after chlorinating and flushing
Test Result Limit or usual range
Coliform bacteria Absent Absent
E. coli Absent Absent
Test Result Limit or usual range
Nitrate, as nitrogen 0.8 mg/L 10 mg/L
Arsenic under 1 µg/L 10 µg/L
Iron 0.4 mg/L 0.3 mg/L (taste and staining only)
Hardness 8 grains per gallon moderately hard
pH 7.4 6.5 to 8.5
Tested by Three Rivers Water Laboratory, Rhinelander, sample 20-07-3318, reported July 27,
2020. The water is safe to drink. The iron is a little over the level at which it stains fixtures; a
filter is optional.
Charges
Amount
Pump, pipe, cable and fittings $1,640.00
Pressure tank, switch and gauge $585.00
Labor, Sunday rate, two men $780.00
Chlorination and water test $145.00
Total, paid by check $3,150.00
The pump and tank are warranted for five years, to July 21, 2025. Turn breaker 14 off before
the lines are drained in the fall; a pump that runs dry is not covered.
Comments
0
Comments are added in the local viewer; this copy is read-only.
Values from records
3render unknown
The record values this file is made from: the ones its text names with {{record.field}}, and the fields its template reads. A value here is in the file's source; whether it is readable depends on the look.
| Value | Now |
|---|---|
| receipt-cabin-well-pump-2020.purchase_date | 2020-07-21 |
| receipt-cabin-well-pump-2020.price | 3150.0 |
| warranty-cabin-well-pump.expiration | 2025-07-21 |
The values at render time were not recorded: the file was rendered before files/rendered.json existed. Rendering it again records them.